logo

Standards Manage Your Business

We Manage Your Standards

ASTM

ASTM D4599 : 14

Standard Practice for Measuring the Concentration of Toxic Gases or Vapors Using Length-of-Stain Dosimeters

Standard Details

1.1 This practice describes the detection and measurement of time weighted average (TWA) concentrations of toxic gases or vapors using length-of-stain colorimetric dosimeter tubes. A list of some of the gases and vapors that can be detected by this practice is provided in Annex A1. This list is given as a guide and should be considered neither absolute nor complete.

1.2 Length-of-stain colorimetric dosimeters work by diffusional sampling. The results are immediately available by visual observation; thus no auxiliary sampling, test, nor analysis equipment are needed. The dosimeters, therefore, are extremely simple to use and very cost effective.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status : Historical
Standard Type: Main
Document No: ASTM D4599 : 14
Document Year: 2014
Pages: 5
  • Section Volume:
  • 11.07 Volume 11.07 Air Quality
  • ICS:
  • 13.320 Alarm and warning systems