1.1 This practice covers the requirements for inspection and acceptance of installed reinforced concrete pipe by either person-entry, or remote inspection as shown in Figs. 1 and 2, respectively.

FIG. 1 Person Entry Inspection

Person Entry Inspection

FIG. 2 Remote Inspection Camera

Remote Inspection Camera

1.2 The scope of this specification is intended for installation related observations and assumes that pre-installation inspection has been completed.

1.3 The reinforced concrete culvert, storm drain and storm sewer pipe shall be manufactured in accordance with Specification C76, C506, C507, C655, C1417, or C1846/C1846M and accepted in accordance with AASHTO R 73. This specification shall only be used for gravity, non-pressure storm drainage applications.

1.4 Person Entry shall be used unless extenuating circumstances preclude this type inspection. Remote inspection is acceptable for use for pipe diameters of 30 in. [750 mm] and smaller unless otherwise specified by owner or engineer.

1.5 Access of installed pipe for manual inspection shall follow OSHA 29 CFR PART 1926 SUBPART AA regulations for confined space entry. However, this standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.6 This practice does not cover deformation or deflection assessment. Concrete pipe is classified as a rigid structure because they do not bend or deflect appreciably under load before cracking. Due to these facts shape evaluation are of little or no value when evaluating concrete pipe.

1.7 The values stated in either Imperial/US or [SI units] are to be regarded separately as standard. The SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International StandardDetails, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status : Historical
Standard Type: Main
Document No: ASTM C1840/C1840M : 22
Document Year: 2022
Pages: 9
  • Section Volume:
  • 04.05 Volume 04.05 Chemical-Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete
  • ICS:
  • 23.040.50 Pipes and fittings of other materials

Life Cycle

Currently Viewing

Historical
ASTM C1840/C1840M : 22
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2024 BSB Edge Private Limited.

Enquire now +