Standard Practice for Continuity Verification of Liquid or Sheet Linings Applied to Concrete Substrates
1.1 This practice covers procedures that may be used to allow the detection of discontinuities in nonconductive linings or other non-conductive coatings applied to concrete substrates.
1.2 Discontinuities may include pinholes, internal voids, holidays, cracks, and conductive inclusions.
1.3 This practice describes detection of discontinuities utilizing a high voltage spark tester using either pulsed or continuous dc voltage.
Note 1—For further information on discontinuity testing refer to NACE Standard RP0188-88 or Practice D 5162
1.4 This practice describes procedures both with and without the use of a conductive underlayment.
1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 7.
Currently Viewing
Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!
© Copyright 2024 BSB Edge Private Limited.