logo

Standards Manage Your Business

We Manage Your Standards

IEC

IEC 60335-2-40:2024 EXV-CMV

Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers

Standard Details

This pack contains IEC 60335-2-40:2024 EXV and IEC 60355-2-40:2024 CMV.

IEC 60335-2-40:2024 deals with the safety of electric heat pumps, sanitary hot water heat pumps and air conditioners, incorporating motor-compressors as well as hydronic fan coils units, dehumidifiers (with or without motor-compressors), thermoelectric heat pumps and partial units, their maximum rated voltage being not more than 300 V for single phase appliances and 600 V for other appliances including direct current (DC) supplied appliances and battery-operated appliances.
Appliances not intended for normal household use but which nevertheless can be a source of danger to the public, such as appliances intended to be used by laypersons in shops, in light industry and on farms, are within the scope of this standard.
The appliances referenced above can consist of one or more factory-made assemblies. If provided in more than one assembly, the separate assemblies are used together, and the requirements are based on the use of matched assemblies.
A definition of ‘motor-compressor’ is given in IEC 60335-2-34, which includes the statement that the term motor-compressor is used to designate either a hermetic motor-compressor or semi-hermetic motor-compressor.
Requirements for containers intended for storage of the heated water included in sanitary hot water heat pumps are, in addition, covered by IEC 60335-2-21.
This standard does not take into account refrigerants other than group A1, A2L, A2 and A3 as defined by ISO 817. Flammable refrigerants are limited to those of a molar mass of more than or equal to 42 kg/kmol based on WCF (worst case formulation) as specified in ISO 817.
As far as practical, this standard deals with common hazards presented by appliances that are encountered in normal use and assumes that installation, servicing, decommissioning, and disposal are safely handled by competent persons and accidental release of refrigerants is avoided. However, it does not specify the criteria to ensure competence of persons during installation, servicing and disposal. Safety requirements during disposal are not specified in this standard.
Annex HH provides informative requirements on competence of personnel. Criteria for competence of personnel for the purpose of certification schemes can be found in ISO 22712.
Unless specifications are covered by this standard, including the annexes, requirements for refrigerating safety are covered by:
– ISO 5149-1:2014, ISO 5149-1:2014/AMD1:2015, and ISO 5149-1:2014/AMD2:2021,
– ISO 5149-2:2014 and ISO 5149-2:2014/AMD1:2020,
– ISO 5149-3:2014 and ISO 5149-3:2014/AMD1:2021.
Supplementary heaters, or a provision for their separate installation, are within the scope of this standard, but only heaters which are designed as a part of the appliance package, the controls being incorporated in the appliance.
Attention is drawn to the fact that
– for appliances intended to be used in vehicles or on-board ships or aircraft, additional requirements can be necessary;
– in many countries, additional requirements are specified, for example, by the national health authorities responsible for the protection of labour and the national authorities responsible for storage, transportation, building constructions and installations.
This standard does not apply to
– humidifiers intended for use with heating and cooling equipment (IEC 60335-2-88);
– appliances designed exclusively for industrial processing;
– appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
This eighth edition cancels and replaces the seventh edition published in 2022. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Clause 12 : Part 1, Clause 12 has been made applicable;
b) Clause 19: requirement added for double wall heat exchangers to be resistant against freezing;
c) Clause 20: requirement modified for when to apply test probe 18;
d) Clause 21: requirement added for double wall heat exchangers to resistant against the pressure of the refrigerant if one of the walls fails;
e) Clause 22: requirement modified to reflect that appliances can operate continuously and can be operated remotely without giving rise to a hazard, and requirement added for double wall heat exchangers to be constructed to avoid refrigerant leaking into the secondary circuit;
f) Annex LL has been deleted and replaced by a reference to IEC TS 63542:2024.
This part 2 is to be used in conjunction with the latest edition of IEC 60335-1 and its amendments unless that edition precludes it; in that case, the latest edition that does not preclude it is used. It was established on the basis of the sixth edition (2020) of that standard.

General Information

Status : ACTIVE
Standard Type: Main
Document No: IEC 60335-2-40:2024 EXV-CMV
Document Year: 2024
Pages: 1115
Edition: 8.0
  • Section Volume:
  • TC 61.SC 61D Appliances for air-conditioning for household and similar purposes
  • ICS:
  • 23.120 Ventilators. Fans. Air-conditioners

Life Cycle

Currently Viewing

ACTIVE
IEC 60335-2-40:2024 EXV-CMV
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2024 BSB Edge Private Limited.

Enquire now +