ISO 4802-2:1988

Glassware — Hydrolytic resistance of the interior surfaces of glass containers — Part 2: Determination by flame spectrometry and classification

Standard Details

The containers are subjected to attack by 121 degrees centigrade for 60 min. The resistance is measured by determining the amount of sodium or other alkali metal or alkaline earth oxides in the extraction solution using flame atomic emission or obsorption spectrometry. The principle, reagents, apparatus and procedure including the classification of the container according to the hydrolytic resistance are specified.

General Information

Status : WITHDRAWN
Standard Type: Main
Document No: ISO 4802-2:1988
Document Year: 1988
Pages: 8
Edition: 1
  • Section Volume:
  • ISO/TC 76. Transfusion, infusion and injection, and blood processing equipment for medical and pharmaceutical use
  • ICS:
  • 71.040.20 Laboratory ware and related apparatus

Life Cycle

WITHDRAWN