logo

Standards Manage Your Business

We Manage Your Standards

ISO

ISO 2719:2002

Determination of flash point — Pensky-Martens closed cup method

Standard Details

ISO 2719:2002 describes two procedures, A and B, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions and other liquids. It is applicable for liquids with a flash point above 40 degrees C.

Procedure A is used for the determination of the flash point of paints and varnishes that do not form a surface film, unused lubricating oils and other petroleum products not covered by Procedure B.

Procedure B is used for the determination of the flash point of residual fuel oils, cutback bitumens, used lubricating oils, liquids that tend to form a surface film, liquids with suspensions of solids and highly viscous materials such as polymeric solutions and adhesives.

ISO 2719:2002 is not applicable to water-borne paints or liquids contaminated by traces of highly volatile materials.

General Information

Status : WITHDRAWN
Standard Type: Main
Document No: ISO 2719:2002
Document Year: 2002
Pages: 21
Edition: 3
  • Section Volume:
  • ISO/TC 28. Petroleum and related products, fuels and lubricants from natural or synthetic sources
  • ICS:
  • 75.080 Petroleum products in general