logo

Standards Manage Your Business

We Manage Your Standards

CSA

C22.1-18

Canadian Electrical Code, Part I (24th Edition), Safety Standard for Electrical Installations

Standard Details

Preface This twenty-fourth edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2017 meetings in Halifax, Nova Scotia. This twenty-fourth edition supersedes the previous editions, published in 2015, 2012, 2009, 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927.  This edition features important revisions to many Sections. Section 26 now mandates the use of tamper-resistant receptacles in additional areas where children may be present. Section 62 now requires ground fault circuit interrupter protection for heating devices and controls in proximity to tubs, sinks, and shower stalls.  Section 10 has been updated, reorganized, and significantly reduced in length. Requirements for power over ethernet systems have been added to Section 16, and requirements for marinas, wharves, and similar facilities have been substantially updated and reorganized in Section 78.  To address the increasing use of electric vehicles, Section 8 now formally recognizes energy management systems as a method of reducing the load on building services. Because lighting control devices associated with energy management or home automation require power to operate, Section 4 now requires that an identified conductor be provided for all devices controlling permanently installed luminaires.  Other revisions in this edition include the following:   in Section 26, Rules 26-400 to 26-726 have been reorganized and renumbered in order to group related concepts together and provide a more logical flow for the requirements; in many Sections, the redundant use of the term “approved” has been eliminated; clarification has been provided on arc-fault circuit interrupter protection for bathrooms, washrooms, existing circuits, and circuits supplying carbon monoxide or smoke alarms; requirements for dining area and refrigerator circuits have been clarified;  the terms “jacketed”, “insulated”, and “covered” as applied to conductors have been clarified through a new definition of the term “jacket” and a revised definition of the term “conductor” in Section 0. As a result, the term “conductor” has been replaced with “insulated conductor” in many Sections of the Code;  Section 82 has been deleted as it covered a technology that is no longer in use; and  a new Appendix M containing French translations of markings has been added. Many of the changes in this edition were developed by cross-functional working groups. Their work is gratefully acknowledged.  General arrangement The Code is divided into numbered Sections, each covering some main division of the work. Sections 0 to 16 and 26 are considered general sections, and the other sections supplement or amend the general sections. The Sections are divided into numbered Rules, with captions for easy reference, as follows: a) Numbering system - With the exception of Section 38, even numbers have been used throughout to identify Sections and Rules. Rule numbers consist of the Section number separated by a hyphen from the 3- or 4-digit figure. The intention in general is that odd numbers may be used for new Rules required by interim revisions. Due to the introduction of some new Rules and the deletion of some existing Rules during the revision of each edition, the Rule numbers for any particular requirement are not always the same in successive editions. b) Subdivision of Rules - Rules are subdivided in the manner illustrated by Rules 8-204 and 8-206, and the subdivisions are identified as follows: 00-000

General Information

Status : ACTIVE
Standard Type: Main
Document No: C22.1-18
Document Year: 2018
Pages: 937
Adopted: No

Life Cycle

Currently Viewing

ACTIVE
C22.1-18

ACTIVE
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2024 BSB Edge Private Limited.

Enquire now +