C22.1-15
Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
Standard Details
Preface This twenty-third edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2014 meetings in Victoria, British Columbia. This twenty-third edition supersedes the previous editions, published in 2012, 2009, 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927. This edition features important revisions to many Sections. Section 4 now contains requirements for high-voltage cable ampacities and clarified Rules for conductor termination temperature. In addition, a new table (Table 39) simplifies residential service and feeder conductor selection. More options are provided for load and voltage drop calculations. Bonding conductor selection has been clarified through the addition of the new Tables 16A and 16B. In addition, Section 12 contains many new and revised requirements for wiring methods, and the conduit fill tables have been expanded. Section 18 has undergone major revisions. Requirements for Class II and Class III locations have been relocated to Appendix J, and requirements for explosive dust atmospheres based on IEC Zone 20, Zone 21, and Zone 22 have been added to Section 18. The requirements are now located as follows: Zones 0, 1, 2, 20, 21, and 22 - Section 18 Classes I, II, and III and associated Divisions - Appendix J Note: References to Class I alone are intended as general references to all classifications of explosive gas atmospheres, Zone 0, Zone 1, and Zone 2. References to Class II alone or to Class III alone are intended as general references to all classifications of explosive dust atmospheres, Zone 20, Zone 21, and Zone 22. Specific references to a Zone of a Class I location are references to that Zone. There are currently no references to Zones or Divisions of Class II or Class III locations in the body of the Rules of this Code (i.e., Sections 0 to 86). Other revisions in this edition include the following: requirements for arc-fault protection have been expanded and clarified; Section 50 has been merged with Section 64; Section 62 has been completely rewritten; and the term "injury" has been replaced with "damage" throughout the Code. Many of the changes in this edition were developed by cross-functional working groups. Their work is gratefully acknowledged. General arrangement The Code is divided into numbered Sections, each covering some main division of the work. Sections 0 to 16 and 26 are considered general sections, and the other sections supplement or amend the general sections. The Sections are divided into numbered Rules, with captions for easy reference, as follows: Numbering system - With the exception of Section 38, even numbers have been used throughout to identify Sections and Rules. Rule numbers consist of the Section number separated by a hyphen from the 3- or 4-digit figure. The intention in general is that odd numbers may be used for new Rules required by interim revisions. Due to the introduction of some new Rules and the deletion of some existing Rules during the revision of each edition, the Rule numbers for any particular requirement are not always the same in successive editions. Subdivision of Rules - Rules are subdivided in the manner illustrated by Rules 8-204 and 8-206, and the subdivisions are identified as follows: 00-000
General Information
Status : ACTIVE
Standard Type: Main
Document No: C22.1-15
Document Year: 2015
Pages: 741
Adopted: No