logo

Standards Manage Your Business

We Manage Your Standards

CSA

CSA ISO 5367:19

Anaesthetic and respiratory equipment — Breathing sets and connectors (Adopted ISO 5367:2014, fifth edition, 2014-10-15)

Standard Details

CSA Preface This is the second edition of CSA ISO 5367-19, Anaesthetic and respiratory equipment — Breathing sets and connectors, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 5367 (fifth edition, 2014-10-15). It supersedes the previous edition published in 2014 as CAN/CSA-ISO 5367, Breathing tubes intended for use with anaesthetic apparatus and ventilators (adopted ISO 5367:2000). For brevity, this Standard will be referred to as “CSA ISO 5367 “throughout. This Standard was reviewed for Canadian adoption by the CSA Technical Committee on Perioperative Safety, under the jurisdiction of the CSA Strategic Steering Committee on Health Care Technology & Systems, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope *This International Standard specifies basic requirements for breathing sets and breathing tubes intended to be used with anaesthetic breathing systems, ventilator breathing systems, humidifiers or nebulizers. It applies to breathing sets and breathing tubes and patient end adaptors supplied already assembled and to those supplied as components and assembled in accordance with the manufacturer’s instructions. This International Standard is applicable to breathing sets which include special components (e.g. water traps) between the patient end and machine end which are supplied already assembled. This International Standard is not applicable to breathing sets and breathing tubes for special purposes. EXAMPLE 1 Ventilators having special compliance, pressure or breathing frequency requirements. EXAMPLE 2 High Frequency Oscillatory Ventilation, (HFOV) or High Frequency Jet Ventilation (HFJV). EXAMPLE 3 Breathing sets and breathing tubes with special connectors for neonatal ventilation. Provision is made for coaxial and related bifurcated, double-lumen, or multiple-lumen breathing sets and breathing tubes suitable for use with patient end adaptors. NOTE 1 Examples of various types of breathing sets with patient end adaptors are depicted in Annex A. Requirements for exhalation valves, exhaust valves, adjustable pressure-limiting (APL) valves, heat and moisture exchangers (HMEs), breathing filters, and reservoir bags, if provided, are not covered by this International Standard. NOTE 2 ISO 80601-2-12, ISO 80601-2-13, ISO 9360-1[3], ISO 23328-2[4], and ISO 5362[1] cover these. NOTE 3 Certain aspects of heated-wire breathing tubes are discussed in ISO 8185[2].

General Information

Status : ACTIVE
Standard Type: Main
Document No: CSA ISO 5367:19
Document Year: 2019
Pages: 52
Adopted: Yes

Life Cycle

Currently Viewing

ACTIVE
CSA ISO 5367:19
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2024 BSB Edge Private Limited.

Enquire now +