logo

Standards Manage Your Business

We Manage Your Standards

ISO

ISO 12884:2000

Ambient air — Determination of total (gas and particle-phase) polycyclic aromatic hydrocarbons — Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analyses

Standard Details

This International Standard specifies sampling, cleanup and analysis procedures for the determination of polycyclic

aromatic hydrocarbons (PAH) in ambient air. It is designed to collect both gas-phase and particulate-phase PAH

and to determine them collectively. It is a high-volume (100 l/min to 250 l/min) method capable of detecting

0,05 ng/m3 or lower concentrations of PAH with sampling volumes up to 350 m3. The method has been validated

for sampling periods up to 24 h.

Precision under normal conditions can be expected to be _ 25 % or better and uncertainty _ 50 % or better (see

annex A, Table A.1).

This International Standard describes a procedure for sampling and analysis for PAH that involves collection from

air on a combination fine-particle filter and sorbent trap, and subsequent analysis by gas chromatography/mass

spectrometry (GC/MS).

General Information

Status : Published
Standard Type: Main
Document No: ISO 12884:2000
Document Year: 2000
Pages: 27
Edition: 1